Integra 1222 Digital Metering System

Integra 1222 Digital Metering System

INTEGRA 1222 multifunction panel meter
LCD Input 480V L-L, 5A / 1A AC
2 pulsed outputs, Modbus RS485.
Q2C plug and socket connectivity

FEATURES
• DIN 96 enclosure
• Backlit LCD screen
• Voltage IN-OUT connections
• CT current measurement
5A/1A
• Plug and socket connections
• Programmable VT, CT ratios
• Modbus™ RTU
• Individual harmonics to 63rd
• Non-volatile memory 1MB
APPLICATIONS
• Commercial Buildings
Disclosures
• Nabers
• National Construction Code
(NCC)
• Greenstar Energy
Management
APPROVALS
• IEC BS EN 61010-1:2010
• BS EN 61326-1:2013
• IEC 62053-21 Class 0.5
• IEC 62053-24 Class 0.5

For more information on the Integra 1222 Digital Metering System Click here.

Get a QUOTE today

 

Short Code

Input - Nominal Input Voltage

57.7 – 276V AC L-N (100-480V L-L)
576V L-L MAX

Input - Max. Continuous Input Overload Voltage

120% of nominal

Input - Max. Short Duration Input Voltage

2 x nominal voltage for 1 second

Input - Nominal Input Voltage Burden

< 0.2VA per phase

Input - Nominal Input Current

1A AC or 5A AC

Input - Nominal Input Current Burden

< 0.1 VA

Input - Max. Continuous Input Overload Current

120% of nominal

Input - Max. Short Duration Input Current (300 msec)

20 x nominal current for 1 second

Auxillary - Operating Range

Self powered (from any of the three phases)

Auxillary - Supply Burden

< 10 VA

Accuracy - Voltage (V)

+/- 0.5% of range maximum

Accuracy - Current (A)

+/- 0.5% of range maximum

Accuracy - Frequency (Hz)

+/- 0.2% of mid-frequency

Accuracy - Power Factor (PF)

+/- 1% of unity (0.01)

Accuracy - Active Power (W)

+/- 1.0% of range maximum

Accuracy - Reactive Power (VAr)

+/- 1.0% of range maximum

Accuracy - Apparent Power (VA)

+/- 1.0% of range maximum

Accuracy - Active Energy (kWh)

Class 1 IEC 62053-21 or Class 0.5 IEC 62053-22

Accuracy - Reactive Energy (kVArh)

Class 2 IEC 62053-23

Accuracy - THD

2% to 63rd harmonic

Measured Range - Voltage (V)

5 – 120% of nominal (Min 100V – self powered)

Measured Range - Current (A)

5 – 120% of nominal

Measured Range - Frequency (Hz)

44 – 66 Hz

Measured Range - Power (W, VAr, VA)

5 – 144% of nominal (bi-directional)

Measured Range - Energy

8 digit, upto 9999999.9 MWh

Measured Range - Power Factor

4 quadrant

Measured Range - THD

0 – 40% upto 63rd harmonic

Environment - Operating Temperature

-25˚C to +55˚C

Environment - Storage Temperature

-40˚C to +70˚C

Environment - Relative Humidity

0 to 95%, non-condensing

Environment - Shock

30g in 3 planes

Environment - Vibration

10Hz to 50Hz, IEC 60068-2-6, 2g

Environment - Dielectric Voltage

4kV between voltage and current to earth

Environment - Altitude

3000m

Environment - Warm-up

1 minute

Outputs - Pulsed Output Relay (configurable)

Opto-coupled, potential-free SPST-NO
contact

Outputs - Contact Rating Current

2-27mA at 27V DC

Outputs - Contact Rating Voltage

5-27V DC

Outputs - Pulse Width

60 / 100 / 200 ms

Outputs - Pulse Rate

0.001/0.01/0.1/1/ 0/100/1000 kWh/kVArh

Outputs - Pulsed Output Relay (Non-Configurable)

3200IMP/kWh

Outputs - Communications

Modbus RTU (RS485)

Outputs - Type

2-wire half duplex

Outputs - Baud Rate

2400, 4800, 9600, 19200, 38400

Outputs - Address

1 to 247

Enclosure - Enclosure Style

DIN 96 panel mount

Enclosure - Dimensions

96x96x62 mm

Enclosure - Panel Cut-Out

92x92mm

Enclosure - Panel Thickness

1-5 mm

Enclosure - Protection Rating

Front IP54, Rear IP30

Enclosure - Material

UL 94-VO

Enclosure - Weight

340 g

Enclosure - Cable Size

0.05mm2 – 2.5mm2 stranded wire

Enclosure - Terminals

Voltage and Current : Shrouded screw clamp

Enclosure - Display Characters

6.2mm