TeSys D Contactor - 4P(2 NO + 2 NC)

TeSys D Contactor - 4P(2 NO + 2 NC)

Pole Description : 4P

Power Pole Contact Composition : 2 NO + 2 NC

Control Circuit Type : AC at 50/60 Hz

Finally, for more information Click here.

Get a QUOTE today

Clear

Pole Description : 4P

Power Pole Contact Composition : 2 NO + 2 NC

Control Circuit Type : AC at 50/60 Hz

Finally, for more information Click here.

Get a QUOTE today

Short Code

, ,

Pole Description

4P

Power Pole Contact Composition

2 NO + 2 NC

[Ue] Rated Operational Voltage

Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC

[Ie] Rated Operational Current

25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

Control Circuit Type

AC at 50/60 Hz

[Uc] Control Circuit Voltage

48 V AC 50/60 Hz

Auxiliary Contact Composition

1 NO + 1 NC

[Uimp] Rated Impulse Withstand Voltage

6 kV conforming to IEC 60947

[Ith] Conventional Free Air Thermal Current

10 A (at 60 °C) for signalling circuit
25 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
40 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
32 A (at 60 °C) for power circuit

Irms Rated Making Capacity

250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
300 A at 440 V for power circuit conforming to IEC 60947

Rated Breaking Capacity

250 A at 440 V for power circuit conforming to IEC 60947, 450 A at 440 V for power circuit conforming to IEC 60947, 300 A at 440 V for power circuit conforming to IEC 60947

[Icw] Rated Short-Time Withstand Current

105 A 40 °C – 10 s for power circuit
210 A 40 °C – 1 s for power circuit
30 A 40 °C – 10 min for power circuit
61 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit, 240 A 40 °C – 10 s for power circuit
380 A 40 °C – 1 s for power circuit
50 A 40 °C – 10 min for power circuit
120 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit, 145 A 40 °C – 10 s for power circuit
240 A 40 °C – 1 s for power circuit
40 A 40 °C – 10 min for power circuit
84 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit

Associated Fuse Rating

10 A gG for signalling circuit conforming to IEC 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
25 A gG at <= 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit conforming to IEC 60947-5-1
50 A gG at <= 690 V coordination type 1 for power circuit
35 A gG at <= 690 V coordination type 2 for power circuit

Average Impedance

2.5 mOhm – Ith 25 A 50 Hz for power circuit, 2 mOhm – Ith 40 A 50 Hz for power circuit, 2.5 mOhm – Ith 32 A 50 Hz for power circuit

[Ui] Rated Insulation Voltage

Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified

Electrical Durability

0.8 Mcycles 25 A AC-1 at Ue <= 440 V, 1.4 Mcycles 40 A AC-1 at Ue <= 440 V, 1 Mcycles 32 A AC-1 at Ue <= 440 V

Mounting Support

Plate
Rail

Connections - Terminals

Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end, Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: connector 1 cable(s) 2.5…10 mm²flexible without cable end
Power circuit: connector 2 cable(s) 2.5…10 mm²flexible without cable end
Power circuit: connector 1 cable(s) 2.5…10 mm²flexible with cable end
Power circuit: connector 2 cable(s) 2.5…10 mm²flexible with cable end
Power circuit: connector 1 cable(s) 2.5…16 mm²solid without cable end
Power circuit: connector 2 cable(s) 2.5…16 mm²solid without cable end, Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: connector 1 cable(s) 2.5…10 mm²flexible without cable end
Power circuit: connector 2 cable(s) 2.5…10 mm²flexible without cable end
Power circuit: connector 1 cable(s) 2.5…10 mm²flexible with cable end
Power circuit: connector 2 cable(s) 2.5…10 mm²flexible with cable end
Power circuit: connector 1 cable(s) 2.5…16 mm²solid without cable end
Power circuit: connector 2 cable(s) 2.5…16 mm²solid without cable end

Tightening Torque

Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2, Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 1.8 N.m – on connector – with screwdriver flat Ø 6 mm
Power circuit: 1.8 N.m – on connector – with screwdriver Philips No 2

Operating Time

4…19 ms opening
12…22 ms closing

Coil Technology

Without built-in suppressor module

Control Circuit Voltage Limits

Drop-out: 0.3…0.6 Uc AC 50/60 Hz (at 60 °C)
Operational: 0.8…1.1 Uc AC 50 Hz (at 60 °C)
Operational: 0.85…1.1 Uc AC 60 Hz (at 60 °C)

Inrush Power in VA

70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in Power Consumption in VA

7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat Dissipation

2…3 W at 50/60 Hz

Auxiliary Contacts Type

type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling Circuit Frequency

25…400 Hz

Minimum Switching Current

5 mA for signalling circuit

Minimum Switching Voltage

17 V for signalling circuit