TL2300 Tungsten Lamp Turbidimeter - EPA - 0-4000NTU

TL2300 Tungsten Lamp Turbidimeter - EPA - 0-4000NTU

Firstly, the new TL23 Series laboratory turbidimeters blend trusted technology. As well as, improved features to simplify testing in the most demanding industrial and wastewater applications.

  • Improved and intuitive design
  • A smart device for more reliable measurements
  • Easy to use. Easy to Be Right
Get a QUOTE today – Call ROI: +353(0)42 950 2210

Price Excluding VAT

£3,361.82

TL2300 Tungsten Lamp Turbidimeter – EPA – 0-4000NTU

Firstly, the new TL23 Series laboratory turbidimeters blend trusted technology. As well as, improved features to simplify testing in the most demanding industrial and wastewater applications.

  • Improved and intuitive design
  • A smart device for more reliable measurements
  • Easy to use. Easy to Be Right

Finally, for more information about the TL2300 Tungsten Lamp Turbidimeter, EPA, 0 – 4000 NTU Click here.

Get a QUOTE today

Short Code

Accuracy

Ratio on: ±2% of reading plus 0.01 NTU from 0 – 1000 NTU, ±5% of reading from 1000 – 4000
NTU based on formazin primary standard
Ratio off: ±2% of reading plus 0.01 NTU from 0 – 40 NTU

Air Purge

Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975)
0.05 L/s at 69 kPa (10 psig); 138 kPa (20 psig) max
Hose barb connection for 1/8-inch tubing

Certifications

CE, KC, RCM

Communication

USB

Data Logging

2000 total logs, includes reading log, verification log and calibration log

Dimensions (H x W x D)

153 mm x 395 mm x 305 mm

Display

17.8 mm colour touch screen

Interface

2 USB-A ports for USB flash drive, external thermal printer, keyboard and barcode scanner

Light Source

Tungsten filament lamp

Measurement Method

Nephelometric

Measuring Range

NTU (Ratio on): 0 – 4000
NTU (Ratio off): 0 – 40
EBC (Ratio on): 0 – 980
EBC (Ratio off): 0 – 9.8

Model

TL2300 EPA

Operating Temperature Range

0 – 40 °C

Power Requirements (Amps)

3.4 A

Power Requirements (Hz)

50/60 Hz

Power Requirements (Voltage)

100 – 240 V AC

Reading Modes

Single, continuous, Rapidly Settling Turbidity, signal averaging on or off, ratio on or off

Regulatory

Meets EPA Method 180.1

Repeatabillity

±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)

Response Time

Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are
used to calculate the average)

Sample Cell Compatabillity

Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps
Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.

Sample Requirements

25 mm sample cell: 20 mL minimum
0 to 70 °C (32 to 158 °F)

Stabilisation Time

Ratio on: 30 minutes after start-up
Ratio off: 60 minutes after start-up

Storage Conditions

-20 – 60 °C

Units

NTU and EBC

Weight

3.0 kg